HP HPE6-A66 dumps

HP HPE6-A66 Exam Dumps

Aruba Certified Design Associate Exam
977 Reviews

Exam Code HPE6-A66
Exam Name Aruba Certified Design Associate Exam
Questions 60 Questions Answers With Explanation
Update Date July 11,2024
Price Was : $81 Today : $45 Was : $99 Today : $55 Was : $117 Today : $65

Prep4Certs: Your Ultimate Destination for Exam Preparation

Are you ready to take your career to the next level with Aruba Certified Design Associate Exam? At Prep4Certs, we're dedicated to helping you achieve your goals by providing high-quality HPE6-A66 Dumps and resources for a wide range of certification exams.

How Can We Help You Prepare for the HP HPE6-A66 Exam?

At Prep4Certs, we're committed to your success in the HP HPE6-A66 exam. Our comprehensive study materials and resources are designed to equip you with the knowledge and skills needed to ace the exam with confidence:

  • In-depth Study Guides: Access detailed study guides covering each exam domain, complete with key concepts, best practices, and real-world scenarios.
  • Practice Exams and Quizzes: Test your knowledge with our collection of practice exams and quizzes, designed to simulate the exam environment and help you gauge your readiness.
  • Interactive Labs and Hands-On Exercises: Reinforce your learning with hands-on labs and interactive exercises that allow you to apply theoretical concepts in practical scenarios.
  • Expert Support and Guidance: Our team of experienced AWS professionals is here to support you every step of the way. Whether you have questions about exam topics or need guidance on exam preparation strategies, we're here to help.

Why Choose Prep4Certs for Your Exam Preparation?

  • Expertly Curated Content: Our study materials are meticulously curated by industry experts and certified professionals to ensure accuracy, relevance, and alignment with exam objectives.
  • User-Friendly Platform: Navigating our platform is easy and intuitive, allowing you to access study materials anytime, anywhere, and from any device. Our user-friendly interface makes it simple to track your progress and focus on areas that require further review.
  • Flexible Learning Options: Whether you prefer self-paced study or structured learning programs, we offer flexible learning options to suit your individual preferences and schedule.
  • Dedicated Support: Have questions or need assistance? Our dedicated support team is here to help. From technical support to exam preparation advice, we're committed to providing you with the assistance you need to succeed.

Start Your Certification Journey Today

Whether you're looking to advance your career, expand your skill set, or pursue new opportunities, Prep4Certs is here to support you on your certification journey. Explore our comprehensive study materials, take your exam preparation to the next level, and unlock new possibilities for professional growth and success.

Ready to achieve your certification goals? Begin your journey with Prep4Certs today!


HP HPE6-A66 Sample Questions

Question # 1

Refer to the exhibit. When planning the use of Cat7 cabling for a SmartRate connection between an ArubaOS AP and an ArubaOS switch, which sections should be considered when calculating distance? 

A. A + C
B. A + B
C. A + B + C + D
D. A + B + C



Question # 2

NewStellar has a main corporate campus in a business park with two adjacent buildings that are 150 feet apart (46 meters). This is an open campus with no obstructions between the two buildings Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire building space. The ceiling for  This floor has a central main corridor with washrooms, stairs, elevators and supply, and network cabinets.There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350square feet (870 square meters).The company has determined that Wi-Fi coverage will not include the central area of each floor, whichincludes the washrooms, stairs, elevators and supply and network cabinets. Based on a capacity design,approximately how many APs should a network architect add to each floor to plan the design in VisuaiRF?

A. 40
B. 10
C. 20
D. 30



Question # 3

A network architect is given the task to design a new network solution for NewStellar Company, Inc. NewSteiiar has a main corporate campus in a business park with two adjacent buildings. The network architect has given one floor to analyze, Building 1 Floor 2, shown in the attached exhibit.  Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235square meters) total, which results in a total of 338,100 feet (31,410 square meters) for the entire buildingspace. Each floor has a central main corridor with washrooms, stairs, elevators and supply and networkcabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensionscontain 9,350 square feet {870 square meters).Because of security concerns, video cameras will be installed throughout the facility. There are 16 of these perfloor, 8 per wiring closet. The cameras are non-WiFi capable and require POE 802.3af-capable switch portsfrom which to draw power.A wireless capacity design is required. Assuming that wireless coverage is required across the Building 1,Floor 2, including the central area, and that half the required APs will connect to each wiring closet,approximately how many POE+ ports will be required per wiring closet for all devices that have POE or POE+needs?

A. 30
B. 22
C. 42
D. 8



Question # 4

NewStellar has a main corporate campus in a business park with two adjacent buildings. Each building has three floors and each floor is 322 x 175 feet (98 x 53 meters) for 56,350 square feet (5,235 square meters) total. The ceiling for each floor is 12 feet (3.6 meters) high with a drop-down ceiling at 10 feet (3 meters). The network architect has given you one floor to analyze, Building 1 Floor 2, shown in the attached exhibit. This floor has a central main corridor with washrooms, stairs, elevators and supply and network cabinets. There are cubicles around the perimeter of the floor. The central part main corridor's dimensions contain 9,350 square feet (870 square meters). Assuming that wireless coverage is not required in the central area, which square footage (square meter) value should a network architect use when determining the number of APs in a capacity design for each floor? 

A. 55.750 square feet {5,175 square meters)
B. 56.350 square feet {5,235 square meters)
C. 47.000 square feet {4,365 square meters)
D. 338,100 feet {31,410 square meters)



Question # 5

A network architect is designing a new wired and wireless solution for for a company. The company has twobuildings on a campus, which each building has three floors. The campus core will be placed in the basementof Building 1. Each wiring closet has eight strands of multi-mode OM3 grade fiber that connect to a wiringcloset of the first floor of the building it is contained, referred to as a main distribution frame (MDF). Themaximum distance between a floor's wiring closet and the MDF is 100 feet (30 meters). The maximumdistance between the two MDFs and the campus core is no more than 150 feet (45 meters). There are eightstrands of multi-mode OM3 grade fiber from these two MDF closets to the campus core.Based on this information, which type of design should be used and what is the maximum speeds supported alluplinks for the existing the multi-mode fiber?

A. three-tier and 10 Gbps
B. three-tier and 40 Gbps
C. two-tier and 10 Gbps
D. two-tier and 40 Gbps



Question # 6

A company has chosen an Aruba mobility controller solution for the redesign of their wireless network Thedesign will have two 7205 controllers in a cluster for campus employees and a single VMC-50 virtualcontroller for remote access via a DMZ. A Mobility Master (MM) is used for centralized license and controllermanagement. All controllers will minimally run ArubaOS 8 4 or later Currently the company has 1.000employees. There are 30 branch offices that will use RAPs to connect to the DMZ controller. A peak of 100users concurrently using the VIA client will also connect to the DMZ controller.How many Aruba LIC-VIA licenses does the company need to purchase for this solution?

A. 100
B. 1
C. 1,030
D. 130



Question # 7

Which IRIS option will automatically create a project with a blank preconfigured Site-1 ?

A. New Campus
B. New Express Mode
C. New Project
D. New Site



Question # 8

A high-end theater venue will be implementing an Aruba wireless solution using ceiling- and wall-mountedAPs. The venue wants to ensure the the APs blend into the ceiling and wall environments. What solutionshould the customer use to ensure that wireless coverage is not hampered?

A. Place the APs above the ceiling and behind the walls
B. Place a strip of tape over the LEDs
C. Order Aruba AP covers for the APs
D. Paint the APs to match the ceilings or walls



Question # 9

A customer requires a campus core virtualization solution that supports a dual control and management planes,as well as active-active forwarding paths. Which solution would meet the customer's requirements?

A. Mesh stacking
B. VSX
C. Backplane stacking
D. VSF



Question # 10

Which must you perform in IRIS to assign a device to a Design Group?

A. Right-click the device and select Set Layer Membership
B. Right-click the device and select Set Design Group
C. Drag and drop the device into the Site
D. Drag and drop the device into the Design Group